An aluminum housing can look tightly closed yet lose electrical continuity across the lid. The contact land, coating and gasket compression need to be treated as an electrical interface, not only a cosmetic joint.
Choose the seal before drawing the groove
Define the shielding requirement, intended gasket product, compression range, lid fastening pattern and environmental seal requirement separately. A conductive gasket need not also be a water seal. Mark cable and connector openings because they can dominate the assembled shielding result.
Machine a continuous contact path
Relate the lid seat, groove depth, stop surfaces and screw bosses to one assembly datum. Keep the contact land clean and free of raised burrs. Specify which areas may be anodized or painted and which require masking or an approved conductive finish; an insulating coating across the contact land can defeat the joint.
Inspect dimensions and assembled continuity
Measure groove geometry, lid flatness and fastener seating. Assemble with the agreed gasket and torque, then check continuity at representative points around the seam and perform the customer's EMC or ingress test if that work is in scope. A bare housing dimension report cannot certify shielding.
Send the actual stack-up for quotation
Provide Vietlink Precision with CAD for both halves, gasket datasheet, finish map, mating hardware, quantity and acceptance method. Clarify whether the order is machined parts only, a fitted enclosure, or a tested assembly.