Gas trapped near the last-fill region may leave a dark mark, but opening a vent too far can create flash. Diagnose the fill path and trial the vent before modifying a production mold.

Locate the last-fill area

Review the actual molded sample, gate position and shot conditions. Mark burn marks, weld lines and any flash on the part rather than changing all vents at once.

Plan a controlled vent

Check parting-line access, insert contact and cleaning access. Agree vent depth and width with the mold owner and resin supplier; avoid copying a generic dimension across materials.

Trial one revision

Machine or EDM the approved vent detail, clean it and run a controlled trial. Compare burn, fill and flash against the previous shot under recorded settings.

Set maintenance criteria

Record insert version, vent position and inspection photos. Check for blocked vents during production; a successful first trial is not a permanent guarantee.