A long connector housing can rock on a PCB or leave an uneven seal even when every local dimension is within tolerance. The inspection method must reproduce the drawing datum without pressing the flexible plastic into an artificial shape. Support, conditioning time and measurement direction are therefore part of the result.
Define the functional plane and the free-state condition
Identify whether the requirement concerns mounting pads, seal flange, terminal plane or the complete housing outline. State the resin, conditioning time after molding, measurement temperature and whether clips, seals or terminals are installed. A free-state warpage check is different from an assembly check at specified screw or latch loads, so both conditions must not share one unnamed limit.
Support the part without removing the defect
Use the minimum stable datum scheme, typically three controlled supports plus gentle lateral location. Avoid broad pads, magnets or clamps that flatten the housing. Keep contact away from ejector marks and gate vestiges, provide clearance for bowed regions and verify the nest with a flat master or calibrated artifact before each production lot.
Measure enough of the surface to describe the shape
A few dial-indicator points can monitor a known mode, while a CMM or optical height map is better for twist and local waves. Report the datum construction, point pattern, maximum and minimum deviations and measurement condition. Correlate the result with PCB seating, seal compression or mating tests before changing the mold or process.